| Thread Tools |
29th September 2009, 12:29 | #11 |
Posts: n/a
| Can't let the unit run longer then a minut other wise my compressor freezes, to much gass on it and bad evap lol Made a new simple design going to call it evap 53 Last edited by Pardons : 29th September 2009 at 12:38. |
29th September 2009, 12:42 | #12 |
Member Join Date: Apr 2005
Posts: 1,338
| make sure u got good hitting space for the gas and u will have a nice evap. thoughe that disign would work nice, with a 3mm thick base.
__________________ http://www.hwbot.org/signature/u5776.png |
29th September 2009, 12:51 | #13 |
Posts: n/a
| |
29th September 2009, 12:52 | #14 |
Member Join Date: Apr 2005
Posts: 1,338
| nope the longer the gas can stay in the evap the beter, but to long is not good also.
__________________ http://www.hwbot.org/signature/u5776.png |
29th September 2009, 13:04 | #15 | |
Posts: n/a
| Quote:
How is your cascade? *edit* could you post what your idea would be as a good evap? tekening ofzo lol ^^ Last edited by Pardons : 29th September 2009 at 13:08. | |
29th September 2009, 13:20 | #16 |
Member Join Date: Apr 2005
Posts: 1,338
| cascade work and is standing right behind me, for evap i would go with maze disign. see XS maybe they got some things u can check. how long is the cap tube ?
__________________ http://www.hwbot.org/signature/u5776.png |
29th September 2009, 13:24 | #17 |
Posts: n/a
| |
1st October 2009, 19:53 | #18 |
Posts: n/a
| At the moment i'm having a vaccuum pump connected to my system, within an hour or so i can tell how much difference my new test with other evap design will give me I hope i can reach at least -1986°c ^^ |
1st October 2009, 20:17 | #19 |
Member Join Date: Apr 2005
Posts: 1,338
| thats the year u where born in .
__________________ http://www.hwbot.org/signature/u5776.png |
2nd October 2009, 15:29 | #20 |
Posts: n/a
| New evap = better results like said This weekend when i have the time i'm going to finetune the system , it reaches easy -45°c and still dropping but i need to insulate the suction line and lett of some gas, (compressor freezing) For now i'm happy My final results will come when i have the time to charge the system with either R410a or R402A, i can expect big improvements with those gasses . I took the R417A cause all other gasses would require new type of oil To make a small compar. R417a = - 41,8 *C, boiling point R507 = - 47.2 *C boiling point in 0 bars. R410a = -48.5 *C boiling point R402a = - 49.2 *C boiling point |
Thread Tools | |
| |